[SCRIPT]Signapk batch file [WINDOWS] - EVO Shift 4G General

So something very simple. Just a little batch file I made but I thought is useful.
NOTE: The point of this batch file is to be able to sign apk's and zips from anywhere in any of your directories, without needing to have the signapk.jar and key files in the same directory. It will not perform any magic and sign system apps with the system signature, or non-system apps with the system signature.
This will sign whatever you give to it...just put it somewhere that is in your path and edit the line that says this:
Code:
set signdir=[U][B]C:\eclipse-adt\cmdtools[/B][/U]
Change C:\eclipse-adt\cmdtools to the path of wherever your signapk.jar file is (your keys should be in that same folder, named publickey.x509.pem and privatekey.pk8).
Example:
Code:
set signdir=[U][B]C:\bill\android\signing-tools[/B][/U]
Anyway, usage for the batch file is as follows (also tells you usage if you pass no parameters to the batch file, e.g. just call signapk).
Code:
Signapk.bat: Sign files from anywhere
Usage: signapk inFile [outfile]
Examples:
signapk mod1.zip [implicit 2nd parameter of mod1-signed.zip]
signapk mod1.zip finalMod.zip
signapk frameworkTW.apk softkeyHack.apk
First example will output a mod1-signed.zip as the signed version of mod1.zip.
Second example will output finalMod.zip as the signed version of mod1.zip.
Third example will output fsoftkeyHack.apk as the signed version of frameworkTW.apk.
Note that if you only pass ONE parameter to the batch file (e.g. the file to sign), then the output file will ALWAYS be named <fileName>-signed.<extension>, as mod1.zip created a mod1-signed.zip output in the example above.
So yeah. Very simple, but I was getting tired of copying my files to my signapk directory and then copying back...so just thought I should share.
If you don't feel like downloading the file, you can create it yourself by copying the content from here: pastebin.com/u6Zj3rsH and pasting it into a file named "<FILE_NAME_HERE>.bat".
Download:
Code:
e1d7016e1b56aa32824974125a424869 *signapk.zip

Related

Build Cab File of an app

Hey Guys!
How can i Build a cab for my programs in vs2005 or have i to use another tool to do this?
thanks SciLor
WinCe cab manager does the job.
its not free though.
but its worth it
isnt there another tool i can use?
look in the Visual studio's help file on making an installer..i cant remember now but i did create a cab once..btw which version of VS do u use
This is from My VS 2008 Pro Documentation
This section describes creating CAB files for distributing ATL and MFC controls over the Internet. If you need more information about CAB files, see the Cabinet File Reference in the Windows SDK documentation (in MSDN Library/Setup and System Administration/Setup/Setup API/Overview/Cabinet Files).
To create a CAB file:
Create an INF file.
Run the CABARC utility.
Creating an INF File
The INF file is a text file that specifies the files (such as DLLs or other OCXs) that need to be present or downloaded for your control to run. An INF file allows you to bundle all the needed files in one compressed CAB file. By default, files with the same version numbers as existing files on the user's hard disk will not be downloaded. For more information about INF files and their options, including how to create platform-independent INF files, see About INF Files and Using INF Files in the Windows SDK documentation (in MSDN Library/Setup and System Administration/Setup/Setup API/Overview/Setup Applications).
As an example, the following INF will be used to create a CAB file for the ATL Polygon control. You can build POLYGON.DLL by downloading the ATL POLYGON sample files from the Visual C++ CD and building a MinSize version. If you build a MinSize version of the Polygon control, you need one additional DLL, ATL.DLL. Since ATL.DLL needs to be registered before POLYGON.DLL, put the ATL.DLL first in the INF file:
Copy Code
; Sample INF file for POLYGON.DLL
[version]
; version signature (same for both NT and Win95) do not remove
signature="$CHICAGO$"
AdvancedINF=2.0
[Add.Code]
polygon.dll=polygon.dll
atl.dll=atl.dll
; needed DLL
[atl.dll]
file-win32-x86=thiscab
FileVersion=2,00,0,7024
DestDir=11
RegisterServer=yes
[polygon.dll]
file-win32-x86=thiscab
clsid={4CBBC676-507F-11D0-B98B-000000000000}
FileVersion=1,0,0,1
RegisterServer=yes
; end of INF file
This INF specifies that ATL.DLL with the given version needs to be installed on the system. If ATL.DLL doesn't exist already on the system, it will be downloaded from the CAB file created with this INF. "thiscab" is a keyword meaning the CAB containing this INF. You can also download a needed DLL from an HTTP location by specifying an absolute or relative path, for example:
Copy Code
file-win32-x86=http://example.microsoft.com/mydir/NEEDED.DLL
The keyword "file-win32-x86" identifies the platform as x86 specific.
You can get the version number of a file by clicking the right mouse button on the file in Windows Explorer. Select Properties from the list that appears, then select the Version tab on the dialog box that appears. You will sometimes need to insert an extra 0 in the file version. For example, the version number for the ATL.DLL is shown as 2.00.7024 in the dialog box. This becomes 2, 00, 0, 7024 in the INF file.
The "DestDir" is where the directory where the file will be loaded: 11 specifies the system directory WINDOWS/SYSTEM or WINNT/SYSTEM32; 10 specifies the windows directory, WINDOWS or WINNT. If no DestDir is specified (typical case), code is installed in the fixed OCCACHE directory.
The "clsid" is the CLSID of the control to be installed.
Once you have created an INF file, run the CABARC utility (available in the Mssdk\Bin directory) to create the CAB file. You should run CABARC in the directory that contains your source files. On the command line, put the source files in the order they appear in the INF and the INF file last. For example, to make a CAB file for the Polygon control from the INF above, use the following command:
Copy Code
C:\MSSDK\BIN\CABARC -s 6144 POLYGON.CAB ATL.DLL POLYGON.DLL POLYGON.INF
The POLYGON.CAB file contains a compressed version of ATL.DLL and POLYGON.DLL along with the information needed to extract them in the POLYGON.INF file.
For an example of how to parse and extract component files from CAB files, see the CabView sample in the MSDN Online Code Center at http://msdn.microsoft.com/visualc/downloads/samples.asp (select the CabView link).
The DLL files you need to include with an MFC control are MSVCRT.DLL, MFC42.DLL, and OLEPRO32.DLL.
Running the CABARC Utility
The CABARC utility is available in the Mssdk\Bin directory. For example:
Copy Code
C:\MSSDK\BIN\CABARC -s 6144 n MYCTL.CAB NEEDED1.DLL NEEDED2.DLL MYCTL.OCX MYCTL.INF
CABARC creates a CAB file called MYCTL.CAB.
You should run CABARC in the directory that contains your source files (the INF, OCX, and DLL files). The files to be archived in the CAB file should be listed on the command line in the same order they are listed in the INF file. In the example above, the INF file should list NEEDED1.DLL first, then NEEDED2.DLL, and then MYCTL.OCX.
The -s option reserves space in the cabinet for code signing. The n command specifies that you want to create a CAB file. For a list of CABARC commands and options, type CABARC alone on the command line:
Copy Code
C:\MSSDK\BIN\CABARC
Click to expand...
Click to collapse
I found an older version of this online:
http://www.aperitto.com/content/view/14/159/
I have version 2.0 and it works great without registering the copy. Look into it
I can't find the original setup I used... sorry, I will keep looking... but I've heard good things about SPB's installatation creator
http://www.spbsoftwarehouse.com/products/ezsetup/index.html?en
It is easy with VS 2008 there you can create a CAB Builder

MSCEInf version 2.1 (Update)

MSCEINf update is only for those who want to use the program in Command Mode for making batch tasks.
Contributions of version 2.1
· MSCEInf Version 2.1 adds ability to extract in command mode CAB files in a folder preserving subfolders names.
Syntax is a bit rigid with a keyword extract (separed by a space) after CAB name. This keyword allows creation of INF file and files extraction (with correct names) while preserving subfolders names.
A second parameter optional is folder name where to extract files. If omitted, folder name will be :
"c:\ExtractDir".
Program creates the folder if it does not exist.
For example write like here (do not forget to separe each parameters by a space and put path in double quotes) :
msceinf "C:\Users\Benoit\Documents\a.cab" extract​and files are extracted in folder "c:\ExtractDir".
or give folder name where to extract :
msceinf "C:\Users\Benoit\Documents\a.cab" extract "C:\Users\Benoit\Documents\My extracted files"​and files are extracted in folder "C:\Users\Benoit\Documents\My extracted files".
Link to the 6 localized versions (include english) : http://www.codeppc.com/telechargements/msceinf/msceinf.htm
.
WOW...great work benthon..it will become handy in making OEMS while cooking

SDConfigGen - a tool for automatically creating SDAutorun configurations

First off, I'd like to thank Sleuth255 for SDAutoRun, and to mousio for his AutoRun tool which provided the inspiration for this project.
SDConfigGen is a command line tool for the PC which inspects a collection of files to be installed, then produces an SDConfig.txt and other associated scripts and provisioning files to allow SDAutoRun to automatically install them.
It differs from mousio's solution in that rather than having SDAutoRun call a MortScript to do all the work, this tool creates an SDConfig.txt to do the majority, only calling scripts for specific functionality when required. Scripts (and therefore MortScript) may not even be required, if nothing being installed needs automation.
Installation
Unzipping the contents of the archive will produce this folder structure:
\
Storage Card\SDConfig\Cabs\
Files\
Scripts\
Settings\
Sys\​First things first - to use any of the script-based functionality a copy of the MortScript installation cab file must be placed within the Sys folder. Download MortScript-4.11b7.zip (or newer version) from http://www.sto-helit.de, then extract \cab\MortScript-4.11b7-PPC.cab from it.
Usage
If the name of the Storage Card will be different on your target device, then rename that folder to whatever it will be. Otherwise, just leave it as it is.
Within the sub-folders of SDConfig, add the files you want to be installed.
Cabs:
Any .cab files in this folder will be installed. If the installation of a .cab file requires user interaction (to confirm a license window, for example), then create a .mscr script file of the same name containing instructions to be executed while the cab file is being installed.
For example, if you need to install a cab file: "eWallet-PocketPC-Install.cab",
create a file called "eWallet-PocketPC-Install.mscr" too. This file contains
MortScript to be run while the cab installer is being run, for example:
Code:
windowTitle = "Software License Agreement"
WaitFor(windowTitle, 60)
SendLeftSoft(windowTitle)
Note that you don't need to worry about actually installing the cab, or waiting for installation to finish - just write the automation code itself.
The SDAutoRun UI will be hidden while an interactive cab is being installed like this, and a MortScript status window shown instead. The device will be responsive to user input, so if any non-automatable interaction is required, that can be done manually.
Files:
After the cab files have been installed, all files in this folder will be copied directly to the root folder. To copy files to sub-folders, place them in sub-folders of this folder. For example, to copy files to the Windows folder, create a Windows folder here and place the files within it.
Standard (English) folder names will automatically be replaced by variables, so files in the "Files\Program Files" folder here will be copied to %CE1% folder by SDAutoRun.
The file copy operation is actually performed by generating a CopyFiles.xml provisioning file in the Sys folder, and it is this that goes in the SDConfig.txt file. This method was chosen as it avoids the path length limit of copying directly in SDConfig.txt, and allows for the %CEn% variable subsitution scheme.
Settings:
After the files have been copied, any settings in this folder will be applied. Settings may either be .xml provisioning files (which are added directly to SDConfig.txt), or registry data in .reg, .rgu or .cereg files. Registry data files will be automatically converted to xml provisioning files within the Sys folder, which are then added to SDConfig.txt.
Scripts:
After the settings have been applied, any .mscr scripts within this folder will be executed. SDConfigGen will generate instructions in SDConfig.txt to automatically handle copying them to the \Temp folder and renaming them to replace spaces by underscores before execution if required.
Note that the device will not be interactive at this point, so don't write scripts that require user interaction.
Sys:
Apart from placing a copy of MortScript-4.11b7-PPC.cab in here, you shouldn't touch the contents of this folder; they will be automatically cleaned out and generated by the SDConfigGen tool.
Notes
I've provided RegToXml as a standalone .exe file so that registry data files can be manually converted to .xml provisioning files, if required. This is not generally necessary, though, as it will occur automatically as part of the SDConfigGen process.
Due to limitations of SDAutoRun, during installation some files need to be copied to the \Temp folder on the device before execution. A TempCleanup.xml provisioning file is generated in the Sys folder by SDConfigGen which is the last thing executed by SDConfig.txt. It should remove any temporary files that were placed in the \Temp folder, but will not remove the folder itself, or any other files within it.
SDAutoRun also requires that SDConfig.txt be ASCII, which means that if any files contain characters outside that range (such as accented characters), they can not be directly referenced. SDConfigGen will automatically detect this, and generate provisioning XML files to transparently rename the files before processing them, then back again afterwards.
The last statement in the SDConfig.txt is the RST: Reset statment, to reset the device.
The only part of the file structure that can be changed is the name of the "Storage Card" folder - the other folders cannot be renamed or moved. By default, when the SDConfigGen tool is run, it works with the first sub folder under the folder the .exe file is placed. To override this behaviour, pass the folder path to SDConfigGen.exe as a command line argument.
Cabs, settings and scripts are executed in alphabetical order, grouped by subfolder. Subfolders will be executed first, so for example the contents of Cabs\Prerequisites\ would be installed before the files directly in Cabs\ (but after files in Cabs\A\). All interactive cabs are executed first, followed by non-interactive ones.
All generated files (except SDConfig.txt) are in Unicode UTF-16 encoding.
To have SDConfigGen create a log file of the generation process, use the SDConfigGenWithLog.bat file included in the archive. It will create a results.log file containing the messages that would normally be output to the console.
This is still an early version, so there will probably be bugs with it. I've used it successfully for setting up my own device several times now, but I can't make any guarantees. Please do post any bug reports or suggestions here though!
Alex
Updates
0.6:
All output files are now in UTF-16 encoding, with the exception of SDConfig.txt, which is in ASCII.
If files referenced by SDConfig.txt have names containing non-ASCII characters, provisioning files to automatically rename them before they are accessed, and to restore them afterwards will be generated.
Subfolders are now supported in the Cabs, Settings and Scripts folders. Files within subfolders will be processed first, in alphabetical order of subfolder name.
File folder variable substition made case insensitive
Added SDConfigGenWithLog.bat file for easy logging of output to a log file
0.5.1:
Removed .svn files from the file structure (oops!)
0.5:
Made warning message on skipping registry files less confusing
RegToXml: Now supports empty values for String, MultiString and Binary values
RegToXml: Made ,ore robust to invalid data - if a value contains invalid data, only that value is skipped.
RegToXml: The line number is now reported with any error or warning message.
RegToXml: Whitespace allowed to surround the = in value lines.
0.4:
RegToXml: Fixed nesting bug with registry key deletion conversion
RegToXml: Now supports comments (lines starting with ; )
0.3:
RegToXml now assumes that registry files without Unicode BOM's are encoded in the system default ANSI codepage, rather than UTF-8 (this means that if your registry file is UTF-8, it must contain a Byte Order Mark to be read correctly)
0.2:
Files are now installed in alphabetical order by file name (within their own group). For example, first interactive cabs A-Z, then non-interactive cabs A-Z. This allows control over installing cabs that require others to be installed before or after them.
.NET Framework (required)
Lookin Mighty Fine Siuer.
Not in the Testing Time yet.
But does the scripts folder eventually combine the scripts into one?
(lazy Bum At Work, Not Able to test it)
No, the scripts in the scripts folder are not combined into a single script, they are all executed separately. Would there be some benefit to trying to combine them into a single script before execution?
AlexVallat said:
No, the scripts in the scripts folder are not combined into a single script, they are all executed separately. Would there be some benefit to trying to combine them into a single script before execution?
Click to expand...
Click to collapse
No, you are absolutely right there is now good reason for it.
It's better to have them seprated, makes finding **** Ups easier.
Don't know what i was thinking or why..
AlexVallat,
Thanks for your job, you soft is amazingly simple which is a great pro compared to SASHIMI for instance.
So yhis afternoon I started to put all my files in the appropriate folders and when I launch SDConfigGen with the folder path I don't get in the config.txt file \Storage Card\ before the files to execute but the path I gave as parameter. I think transforming the path given into \Storage Card\ could help.
One other point, as a poor French guy your RegToXml converter does not handle all the French extended character set such as é, à, ... Could you make it support this characters.
Anyway for now it is fully usable but requires SDConfig.txt file edition before launching the whole process. Tomorrow it will be hands-on time as I plan to upgrade my Polaris ROM so more news to come regarding SDCofingGen usage.
The_Steph
The_Steph said:
AlexVallat,
Thanks for your job, you soft is amazingly simple which is a great pro compared to SASHIMI for instance.
So yhis afternoon I started to put all my files in the appropriate folders and when I launch SDConfigGen with the folder path I don't get in the config.txt file \Storage Card\ before the files to execute but the path I gave as parameter. I think transforming the path given into \Storage Card\ could help.
One other point, as a poor French guy your RegToXml converter does not handle all the French extended character set such as é, à, ... Could you make it support this characters.
Anyway for now it is fully usable but requires SDConfig.txt file edition before launching the whole process. Tomorrow it will be hands-on time as I plan to upgrade my Polaris ROM so more news to come regarding SDCofingGen usage.
The_Steph
Click to expand...
Click to collapse
Hm my pall had the same thing but changing to Unicode seemed to solve his XML issue. NOt sure if this is the same but worth the try.
Great work alex!
Question:
Anyway to verify the syntax of the provisioning XML files?
Any tools out there that can create these files or verify them? I think a tool like this would be great.
NEVERMIND! I just saw your reply in the reg2xml converter thread! THANKS!
The_Steph: Thanks for your comments!
The idea with the path is that the name of the folder is used to control the name of the Storage Card on the device. So if you name your folder Storage Card, that's what goes in the SDConfig.txt. If, on your device, it has a different name (due to language changes, or whatever), then you need to rename the folder appropriately.
Thanks for the bug report about accented characters in RegToXml. I will fix that and post an updated version soon.
gtxaspec: I could verify that the files were valid XML, but the more useful check that they contain valid provisioning instructions is beyond the scope of this project. Not least because the documentation describing what are valid instructions is confusing and can be inaccurate. With anything other than the file and registry providers, it usually ends up being a case of trial and error. With the file and registry providers, using the auto-generation capabilities of SDConfigGen will avoid most surprises.
Alex
Version 0.3 released
I've just updated the first post to release version 0.3. This should address the accented characters issue raised by The_Steph, however it does mean that if your registry file is UTF-8 encoded, it must include Byte Order Marks to indicate this. Otherwise, it will be assumed to be encoded in the system default code page.
I've also added a feature that files are now installed in alphabetical order (within each group). If you need to make sure that certain cabs are installed before others, this can now be done by renaming them, usually by including a numeric prefix.
Alex
reg2xml bugs
Hi Alex,
Converting everything to xml and using standard provisioning is an interesting approach!
Only obviously reg2xml has got some problems still with .reg files containing certain characters:
I've attached you a sample file which is not converted correctly at three points, each with a different error cause.
- Comments (Lines beginning with ";") in the .reg files are sometimes (not in every case, could not see what the trigger is) leading to an aborted conversion.
- Some characters like the arrow character (ASCII 27/1BHex) are also a problem.
Maybe the attached file helps in finding the bug.
BTW: Do you also have a tool that is converting just the other way around: From XML to reg indstead of from reg to XML?
Sometimes I need to have a .reg file instead of an .XML. And importing the XML and then trying to find all registry entries to export it back to a .reg can be a very tedious thing when the imports are not all together in one registry branch.
Thanks!
Thanks for the bug report, asango. Yes, I forgot about comments, I'll fix that and release an update soon. I'm looking into what the best way to handle control characters like 0x1B is (which is 'Escape', according to the ASCII chart I'm looking at). Obviously crashing is not an acceptable behaviour, so I'll have some sort of fix for it.
I don't have a XmlToReg tool, but it sounds like a good idea - I'll probably write one over the weekend.
Alex
Great, looking forward to that, thank you!
Version 0.4 released
The first post has been updated to version 0.4. RegToXml has been updated to add support for comments in .reg files.
Unfortunately there appears to be no way to include control characters in an XML file. If the character itself, or even the character entity (like &#x1B, then the file is regarded as malformed and not accepted. I have therefore not been able to do anything to fix this (sorry asango!).
If anyone knows of a way that a provisioning file could be used to set a registry string value containing these characters, please let me know.
On a more positive note, the requested XmlToReg tool is up - I've given it its own thread here: XmlToReg.
Alex
Yes, the comments are now handled corectly, perfect!
Some other thing is still an issue:
test.reg: Converting...
test.reg: Conversion failed. (Unexpected value format: dword) Skipping.
In this case the output file is not generated at all, seems that not only the value is skipped but this causes the whole file not being written.
This leads to another suggestion: Would it be possible to indicate the line number where a problem happened?
This would make it much easier to find the problem.
And regarding the non handled escape characters:
This also leads to aborting. Would it also be possible to just skip them and issue a warning but go on with the conversion and with writing the outout file for the rest of the entries?
Now that is odd. "dword" is a perfectly valid value format, it shouldn't have produced that error. Any chance you could send me the .reg file that produced it?
Line numbers should be do-able, I'll add that to the next version.
The "skipping" message there referred to the "test.reg" at the start of the message, not to the dword value. I agree it looks misleading as it is currently worded though, I'll improve that.
About recovering from errors and skipping only invalid values rather than the whole file - this will be quite tricky. By the time I am notified of invalid characters by the XmlWriter, it has already given up in a sulk and can't be persuaded to continue writing any further. I'll need to do some sort of pre-vetting before passing data on to it. If I come up with any good ideas on how to do this, I'll include it in the next version.
Alex
asango, here's a candidate RegToXml.0.5.0 - could you check if it is still reporting the "Unexpected value format: dword" error with your file? It now reports line numbers, which might help track down the problem. It should also be able to recover from an invalid value and skip just that value, although I'm not sure how well that is working yet.
Alex
Hi Alex,
Great, the line numbers are making things much easier and this way I even found the reason for this error very easily:
Here's the point where it is failing:
[HKEY_LOCAL_MACHINE\Drivers\BuiltIn\RIL]
"NITZEnable"= dword:00000001
...with this error message:
test.reg: Converting...
[Line 194] Error: Invalid value (Unexpected value format: dword)
Skipping: HKEY_LOCAL_MACHINE\Drivers\BuiltIn\RIL\NITZEnable
Done.
As soon as I'm deleting the blank between the "=" and "dword" everything is ok.
Maybe you can allow blanks after the "=" in general?
This would solve this issue definitely
And yes, by the way the xml file is now generated despite of this error, very good!
Asango
Hmm... I'm not sure whitespace is supposed to be allowed around the = sign. It doesn't make anything ambiguous though, so there's no good reason not to relax the matching. Try this 0.5.1 which allows whitespace around the = sign, hopefully that should now parse your file correctly.
Alex
Yes, now I can see no other issues with the RegToXml tool, good work!
Also the whole cold boot import is ok with one exception:
Only the CopyFiles.xml which is generated by the SDConfigGen.exe is not copying all the files from the "Files" diectory during its execution.
Tried to import that xml manually with the xml option of Taskmgr and also got an error, but since the error is *very* uninformative and not showing the line number and my CopyFiles.xml is rather big I could not find the problem.
Could it be that the reason for the error is that if a file is already existing or read only that this will stop the rest of the import?
asango said:
Yes, now I can see no other issues with the Only the CopyFiles.xml which is generated by the SDConfigGen.exe is not copying all the files from the "Files" diectory during its execution.
Tried to import that xml manually with the xml option of Taskmgr and also got an error, but since the error is *very* uninformative and not showing the line number and my CopyFiles.xml is rather big I could not find the problem.
Click to expand...
Click to collapse
Second hands-on day with SDConfigGen and I have the same issue with v0.4. CopyFiles.xml is not executed at all. Probably a syntax error issue as stated by asango (I've done the same tests as him).
The_Steph

[TOOL][GUI][Reverse engineer] Decompile APK to JAR Full Decompile :: One Click

Reverse engineer "Perfect software" , managed to convert apk to a jar file and decompile it using JD(via dex2jar)
The program uses 3 tools (apktool.jar, dex2jar.bat, jad.exe)
I've updated all lib/scripts ,apktool.jar 1.5.2, dex2jar 0.0.9.15
in attach you will find
Fragment.apk I've tested with this tool and works fully !!,look on OutPut_Fragment.zip to see the result
Download:
DeCompileAPK.zip
To Start
Works on Windows7/8
1. Scan dir for “apk” file or look for the file with “APK File Directory”.
Scan has a “subfolders” flag ,in the “Options” tab.
2. Double click on the found file it will be transferred to the “APK File Directory”.
3. Write or look for the output directory. Leaving this line empty will put all
the project output files under the directory “OutPut” where this program is executed.
If there is an output directory name, a directory “OutPut_” + APK file name
will be created.
3. Press the Decompile KEY.
4. All Dos messages will be seen in the “Decompile OutPut” panel.
5. It will be shown also in the “Edit log” panel.
6. The log can be edited and printed.
7. A java file editor is included. Scan project files, Scan any directory or open any file.
NOTE : USE ONLY ENGLISH CHARACTERS FOR FILE NAMES !
Credit and Thanks !
Tool Dev Website: http://www.limelect.com/android/
Reversed for new stuff
anyone tell us how it works with him?
codexc said:
anyone tell us how it works with him?
Click to expand...
Click to collapse
no download link to test

How can I overwrite a specific variable or line in a .py file?

I have a .txt file, opentime.txt, that contains only one line, a timestamp that updates periodically. I would like to use that timestamp in a python script by overwriting the previous timestamp once per day. Can I write the contents of opentime.txt into a line of the .py file without affecting the rest of the code in that file?

Categories

Resources