We have developped an application on WM2002 and WM2003 that use PDA modem to communicate with a remote device.
We worked with QTEK 2020 and QTEK 9090.
Last month we must porting the application on WM2005 (JAMin PDA), but we founded problems with the AT commands sent on the modem.
The code that open the modem is:
// initialize RIL COM
if (!RIL_Initialize(1, NULL, NULL, 0x00040000L, NULL, &m_hRil))
{
error("RIL_Initialize");
ResTMP= 1;
}
// open COM2 (to send AT command to the modem)
m_hCom=CreateFile(CommandPort,GENERIC_READ|GENERIC_WRITE,0,0,OPEN_EXISTING,0,0);
if (m_hCom==NULL || m_hCom==INVALID_HANDLE_VALUE)
{
error("CreateFile()");
m_hCom= NULL;
return 2;
}
// set COM setting
DCB dcb;
if (!GetCommState(m_hCom, &dcb))
{
error("GetCommState");
ResTMP= 3;
}
dcb.BaudRate= CBR_115200;
dcb.ByteSize= 8;
dcb.fParity= false;
dcb.StopBits= ONESTOPBIT;
if (!SetCommState(m_hCom, &dcb))
{
error("SetCommState");
ResTMP= 4;
}
if (!EscapeCommFunction(m_hCom, SETDTR))
{
error("SETDTR");
ResTMP= 5;
}
COMMTIMEOUTS to;
if (!GetCommTimeouts(m_hCom, &to))
{
error("GetCommTimeouts");
ResTMP= 7;
}
to.ReadIntervalTimeout= 0;
to.ReadTotalTimeoutConstant= 200;
to.ReadTotalTimeoutMultiplier= 0;
to.WriteTotalTimeoutConstant= 20000;
to.WriteTotalTimeoutMultiplier= 0;
if (!SetCommTimeouts(m_hCom, &to))
{
error("SetCommTimeouts");
ResTMP= 8;
}
if (!SetCommMask(m_hCom, EV_RXCHAR))
{
error("SetCommMask");
ResTMP= 9;
}
// open RIL2 (radio)
m_hRil= CreateFile(RadioPort,GENERIC_READ|GENERIC_WRITE, FILE_SHARE_READ|FILE_SHARE_WRITE,0,OPEN_EXISTING,FILE_ATTRIBUTE_SYSTEM,0);
if (m_hRil==NULL || m_hRil==INVALID_HANDLE_VALUE)
{
error("CreateFile()");
return 10;
}
// send command to radio handle to turn off the phone and release the modem
DWORD rildevresult;
if (!DeviceIoControl(m_hRil, 0x03000314L,0,0, &rildevresult, sizeof(DWORD), &nReturned,0))
{
error("DeviceIoControl ril 0x03000314L");
ResTMP= 11;
}
// send command to modem to enable it
BYTE comdevcmd[2]= {0x84, 0x00};
if (!DeviceIoControl(m_hCom,0xAAAA5679L, comdevcmd, sizeof(comdevcmd),0,0,0,0))
{
error("DeviceIoControl com 0xAAAA5679L");
ResTMP= 12;
}
The red code not works on WM2005, therefore the radio is not released and the AT commands sent on COM2 not produce.
Sorry...
the red code is:
if (!DeviceIoControl(m_hRil, 0x03000314L,0,0, &rildevresult, sizeof(DWORD), &nReturned,0))
{
error("DeviceIoControl ril 0x03000314L");
ResTMP= 11;
}
It's great!
mmarco_hes said:
We worked with QTEK 2020 and QTEK 9090.
Last month we must porting the application on WM2005 (JAMin PDA), but we founded problems with the AT commands sent on the modem.
The red code not works on WM2005, therefore the radio is not released and the AT commands sent on COM2 not produce.
Click to expand...
Click to collapse
Some people seem to have solved this. The Universal unlocker on buzzdev.net contains the correct calls. You might want to take a peek at that binary... (IDA required).
bigmac
Hi bigmac, I have not found nothing on buzzdev.net that can help me to solve this problem.
You have any idea how I can found the information in the site buzzdev.net that can help me?
Tank's!
Hi mmarco_hes!
I have the same problem with the "red code" on my WM5 device.
Do you found the reason or a solution for this problem ?
Thank´s in advance.
Regards Jogi
I see COM7 on MDAPro Universal ist GSM/GPRS port. I can open it via createfile, but i can't send DeviceIoControl code:
BYTE comdevcmd[2]= {0x84, 0x00};
if (!DeviceIoControl (m_hCom,0xAAAA5679L, comdevcmd, sizeof(comdevcmd),0,0,0,0))
{
error("DeviceIoControl com 0xAAAA5679L");
return false;
}
What is the real code on MDAPro ?
Related
Hi,
GoodDay. I am using O2 XDAII, I am want to send some data through GSM. For that I want to know, GSM is situated in Which Port ?.......
So that i can Open the port(COM1 or Com2) and send the some AT commands into it.
or is there any there way to Open the GSM and send data
Kindly Let me know..
Thanks
regards,
Rajesh. S
Over GSM, you have two options; dial-up and GPRS..
None of these uses COM ports in the way that you are thinking..
GSM is located at COM2. But to enable communication with it on XDA2 you'll need to send IOCTL to RIL. Here is a code from one of my test applications.
Code:
#include "stdafx.h"
int HexToInt(char R)
{
if(R>='0' && R<='9')
return R-'0';
if(R>='a' && R<='f')
return R-'a'+10;
if(R>='A' && R<='F')
return R-'A'+10;
return 15;
}
int Hex2ToInt(char *R)
{
return ((HexToInt(R[0])<<4)|HexToInt(R[1]))&255;
}
bool IsHex(char C)
{
if(C>='0' && C<='9')
return true;
if(C>='A' && C<='F')
return true;
return false;
}
int WINAPI WinMain( HINSTANCE hInstance,
HINSTANCE hPrevInstance,
LPTSTR lpCmdLine,
int nCmdShow)
{
HANDLE hCom;
char * xpos;
char rsltstr[5];
DWORD CellId;
int bufpos;
DCB dcb;
COMMTIMEOUTS to;
DWORD nWritten;
DWORD event;
DWORD nRead;
static char outbuf[65536], buf[65536];
BYTE comdevcmd[2]= {0x84, 0x00};
FILE *F=fopen("\\Storage Card\\dump.bin","r+bc");
if(F==0)
F=fopen("\\Storage Card\\dump.bin","w+bc");
hCom= CreateFile(L"COM2:",GENERIC_READ|GENERIC_WRITE,0,0,OPEN_EXISTING,0,0);
if (hCom==NULL || hCom==INVALID_HANDLE_VALUE)
{
hCom= NULL;
return -1;
}
HANDLE hRil= CreateFile(L"RIL1:",GENERIC_READ|GENERIC_WRITE,0,0,OPEN_EXISTING,0,0);
if (hRil==NULL || hRil==INVALID_HANDLE_VALUE)
{
hRil= NULL;
return -1;
}
if (!GetCommState(hCom, &dcb))
{
return -2;
}
dcb.BaudRate= CBR_115200;
dcb.ByteSize= 8;
dcb.fParity= false;
dcb.StopBits= ONESTOPBIT;
if (!SetCommState(hCom, &dcb))
{
return -3;
}
if (!EscapeCommFunction(hCom, SETDTR))
{
return -4;
}
if (!EscapeCommFunction(hCom, SETRTS))
{
// return -5;
}
if (!GetCommTimeouts(hCom, &to))
{
return -6;
}
to.ReadIntervalTimeout= 5;
to.ReadTotalTimeoutConstant= 5;
to.ReadTotalTimeoutMultiplier= 5;
to.WriteTotalTimeoutConstant= 20000;
to.WriteTotalTimeoutMultiplier= 0;
if (!SetCommTimeouts(hCom, &to))
{
return -7;
}
if (!SetCommMask(hCom, EV_RXCHAR))
{
return -8;
}
DWORD rildevresult=0,nReturned=0;
// DeviceIoControl(hRil, 0x03000314L,0,0, &rildevresult, sizeof(DWORD), &nReturned,0);
// HANDLE Ev=CreateEvent(NULL,TRUE,0,L"RILDrv_DataMode");
// SetEvent(Ev);
if (!DeviceIoControl (hCom,0xAAAA5679L, comdevcmd, sizeof(comdevcmd),0,0,0,0))
{
return -9;
}
fseek(F,0,SEEK_END);
DWORD Addr=ftell(F);
Rest:
bufpos = 0;
// strcpy(outbuf,"AT%TEST=D00000000\r");
sprintf(outbuf,"AT%%TEST=D%08X\r",Addr);
to.ReadIntervalTimeout= MAXDWORD;
to.ReadTotalTimeoutConstant= 0;
to.ReadTotalTimeoutMultiplier= 0;
to.WriteTotalTimeoutConstant= 20000;
to.WriteTotalTimeoutMultiplier= 0;
if (!SetCommTimeouts(hCom, &to))
{
return -7;
}
ReadFile(hCom, buf, 65536 , &nRead, NULL);
to.ReadIntervalTimeout= 5;
to.ReadTotalTimeoutConstant= 5;
to.ReadTotalTimeoutMultiplier= 5;
to.WriteTotalTimeoutConstant= 20000;
to.WriteTotalTimeoutMultiplier= 0;
if (!SetCommTimeouts(hCom, &to))
{
return -7;
}
if (!WriteFile(hCom, outbuf, strlen(outbuf), &nWritten, NULL))
{
return -10;
}
if (!WaitCommEvent(hCom, &event, NULL))
{
return -12;
}
ReadFile(hCom, buf, 16*78, &nRead, NULL);
char Buff[256];
for(int i=0; i<16; i++)
{
if(buf[i*78+8]!=':' || buf[i*78+9]!=' ')
goto Rest;
for(int j=0; j<16; j++)
{
if(!IsHex(buf[i*78+10+j*3]))
goto Rest;
if(!IsHex(buf[i*78+10+j*3+1]))
goto Rest;
Buff[i*16+j]=Hex2ToInt(buf+i*78+10+j*3);
}
}
Addr+=256;
// fwrite(buf,1,16*78,F);
fwrite(Buff,1,256,F);
fflush(F);
printf("%08X\r",Addr);
goto Rest;
rildevresult = 0;
DeviceIoControl(hRil, 0x03000318L,0,0, &rildevresult, sizeof(DWORD), &nReturned,0);
// ResetEvent(Ev);
// CloseHandle(Ev);
CloseHandle(hRil);
if (!EscapeCommFunction(hCom, CLRDTR))
{
return -4;
}
if (hCom!=NULL)
{
CloseHandle(hCom);
hCom= NULL;
}
return CellId;
}
Hi,
Good Day.. I got your code..... First of all i convey my thanks to you.
I need some more clarification from your side.
Kindly let me know in details
I am not able understand
Why we need to use RIL & IOCTL Funct?
how your sending "AT" Commands in your Code?( explain to me in details) If i want to add some more AT commands like( AT+CSQ or AT^SCKS?) means how do i add these command and where?...
if you have sample code kindly send to [email protected]
anticipating your reply,
Thanks & regards,
Rajesh. S
Sorry !! Mail ID is : [email protected]
Using COM port GSM access to change outgoing line
Is it possible to alter the outgoing number (read from the SIM card) on the GSM by accessing the COM port?
Is there a utility that already does this? Is there a way of altering settings/phone to be able to change the outgoing number? Or a ROM image that allows you to do this?
I have no understanding whatsoever of the radio stack, so I wouldn't know where to start if I were to write a utility to do so.
Cheers,
Jason
jman said:
Is it possible to alter the outgoing number (read from the SIM card) on the GSM by accessing the COM port?
Is there a utility that already does this? Is there a way of altering settings/phone to be able to change the outgoing number? Or a ROM image that allows you to do this?
I have no understanding whatsoever of the radio stack, so I wouldn't know where to start if I were to write a utility to do so.
Cheers,
Jason
Click to expand...
Click to collapse
@jman,
No that is not possible. The reason is that the phone does not send its caller ID over the air. What happens is that a pseudo random number (called TMSI) is assigned to the mobile phone. The mobile phone sends its TMSI for identification and the MSC (Mobile Switching Centre) does the mapping for the TMSI to calling MSISDN (techno term for mobile phone number).
However, if you are a really good programmer and know your phone internal GSM functioning very well. Then you can spoof the TMSI. Meaning, you should listen to the Paging Messages that are being received on the PCH and get the TMSI from them and then generate a CHAN_REQ based on one of those TMSI. If you want to know more about it, then I suggest that you read a document called GSM04.08 from www.3gpp.org .
Please note that whatever I have written above is valid for a GSM/GPRS/EDGE network only.
Regards,
hi
I've been writing code to access the gsm modem of PPCs and SPs. I found these posts http://forum.xda-developers.com/showthread.php?t=220396 and http://forum.xda-developers.com/showthread.php?t=268809 and this one too http://www.nicecuppa.net/nicetrack.asp to name a few.
here is a sample
Code:
PDACELLID_API long fnGetCell(LPTSTR outData)
{
HANDLE hCom;
char * xpos;
char rsltstr[5];
DWORD CellId;
int bufpos;
DCB dcb;
COMMTIMEOUTS to;
DWORD nWritten;
DWORD event;
DWORD nRead;
char outbuf[20], buf[256];
BYTE comdevcmd[2]= {0x84, 0x00};
hCom= CreateFile(L"COM2:",GENERIC_READ|GENERIC_WRITE,0,0,OPEN_EXISTING,0,0);
if (hCom==NULL || hCom==INVALID_HANDLE_VALUE)
{
hCom= NULL;
return -1;
}
if (!GetCommState(hCom, &dcb))
{
return -2;
}
dcb.BaudRate= CBR_115200;
dcb.ByteSize= 8;
dcb.fParity= false;
dcb.StopBits= ONESTOPBIT;
if (!SetCommState(hCom, &dcb))
{
return -3;
}
if (!EscapeCommFunction(hCom, SETDTR))
{
return -4;
}
if (!GetCommTimeouts(hCom, &to))
{
return -6;
}
to.ReadIntervalTimeout= 0;
to.ReadTotalTimeoutConstant= 200;
to.ReadTotalTimeoutMultiplier= 0;
to.WriteTotalTimeoutConstant= 20000;
to.WriteTotalTimeoutMultiplier= 0;
if (!SetCommTimeouts(hCom, &to))
{
return -7;
}
if (!SetCommMask(hCom, EV_RXCHAR))
{
return -8;
}
if (!DeviceIoControl (hCom,0xAAAA5679L, comdevcmd, sizeof(comdevcmd),0,0,0,0))
{
return -9;
}
bufpos = 0;
strcpy(outbuf,"AT+creg=2\r");
if (!WriteFile(hCom, outbuf, 10, &nWritten, NULL))
{
return -10;
}
if (nWritten != 10)
{
return -11;
}
if (!WaitCommEvent(hCom, &event, NULL))
{
return -12;
}
while(1)
{
if (!ReadFile(hCom, buf+bufpos, 256 - bufpos, &nRead, NULL))
{
return -13;
}
if (nRead == 0)
break;
bufpos += nRead;
if (bufpos >= 256)
break;
}
strcpy(outbuf,"AT+creg?\r");
if (!WriteFile(hCom, outbuf, 9, &nWritten, NULL))
{
return -14;
}
if (nWritten != 9)
{
return -15;
}
if (!WaitCommEvent(hCom, &event, NULL))
{
return -16;
}
while(1)
{
if (!ReadFile(hCom, buf+bufpos, 256 - bufpos, &nRead, NULL))
{
return -17;
}
if (nRead == 0)
break;
bufpos += nRead;
if (bufpos >= 256)
break;
}
buf[bufpos] = 0;
mbstowcs(outData,buf,bufpos+1);
if ((xpos = strstr(buf,"CREG")) == NULL)
{
CellId = -19;
}
else
{
memcpy(rsltstr,xpos+18,4);
rsltstr[4] = 0;
if (sscanf(rsltstr,"%X",&CellId) != 1)
{
CellId = -20;
}
}
if (hCom!=NULL)
{
CloseHandle(hCom);
hCom= NULL;
}
return CellId;
}
Some of these posts assume that I already know the com port of the gsm modem, Others tell you to get the com port handle by either:
1- TAPI's lineGetID - which only gets a valid handle if I originate a voice call (not data call). In my case I only query information from the network so I don't need to make a voice call and that is why I'll never get a com port handle.
2- Silent the RIL and open the com port manually as in here
http://forum.xda-developers.com/showpost.php?p=963262&postcount=1
which apparetnly turns on the flight mode and shuts down the phone on WM2005.
3- I tried to detect the right com port using the registry key HKLM\Drivers\BuiltIn\Serial which doesn't give the right result on every device.
In the HTC universal (i-mate jasjar) there is no "known" way to open the GSM com port. Even nicetrack couldn't detect the gsm modem port.
There is definitely a way to get the com port handle but it may involve reverse engineering which i'm not good at. I leave that to the pros
Save me from madness!!!
I have a several smartphone devices with windows CE
CE 6.0 - hp IPAQ 500 series
CE 5.0 - Samsung i600
I need to inject DLL into the process "home.exe". I use method with performcallback4 function. This method works successfully for all processes ("device.exe", "service.exe", etc.) except process "home.exe". In what a problem?
source code : InjectDLL.exe link with toolhelp.lib
#include <windows.h>
#include <Tlhelp32.h>
typedef struct _CALLBACKINFO {
HANDLE hProc;
FARPROC pfn;
PVOID pvArg0;
} CALLBACKINFO;
extern "C"
{
DWORD PerformCallBack4(CALLBACKINFO *pcbi,...);
LPVOID MapPtrToProcess(LPVOID lpv, HANDLE hProc);
BOOL SetKMode(BOOL fMode);
DWORD SetProcPermissions(DWORD newperms);
};
DWORD GetProcessId(WCHAR *wszProcessName)
{
HANDLE hTH= CreateToolhelp32Snapshot(TH32CS_SNAPPROCESS, 0);
PROCESSENTRY32 pe;
pe.dwSize= sizeof(PROCESSENTRY32);
DWORD PID=0;
if (Process32First(hTH, &pe))
{
do {
if (wcsicmp(wszProcessName, pe.szExeFile)==0)
{
PID=pe.th32ProcessID;
}
} while (Process32Next(hTH, &pe));
}
CloseToolhelp32Snapshot(hTH);
return PID;
}
HMODULE GetDllHandle(DWORD ProcessId,WCHAR* ModuleName)
{
HANDLE ToolHelp=CreateToolhelp32Snapshot(TH32CS_SNAPMODULE,ProcessId);
if (ToolHelp!=INVALID_HANDLE_VALUE)
{
MODULEENTRY32 ModuleEntry={sizeof MODULEENTRY32};
if (Module32First(ToolHelp,&ModuleEntry))
do
{
if (wcsicmp(ModuleEntry.szModule, ModuleName)==0)
return ModuleEntry.hModule;
}
while(Module32Next(ToolHelp,&ModuleEntry));
CloseToolhelp32Snapshot(ToolHelp);
}
return NULL;
}
BOOL InjectDll(WCHAR* ProcessName,WCHAR* ModuleName)
{
DWORD ProcessId=GetProcessId(ProcessName);
HMODULE ModuleHandle=GetDllHandle(ProcessId,ModuleName);
if (ModuleHandle!=NULL)
return TRUE;
HANDLE Process=OpenProcess(0,0,ProcessId);
if (Process==NULL)
return FALSE;
void* ModuleNamePtr=MapPtrToProcess(ModuleName,GetCurrentProcess());
if (ModuleNamePtr==NULL)
return FALSE;
CALLBACKINFO ci;
ci.hProc=Process;
void* LoadLibraryPtr=MapPtrToProcess(GetProcAddress(GetModuleHandle(L"coredll.dll"),L"LoadLibraryW"),Process);
if (LoadLibraryPtr==NULL)
return FALSE;
ci.pfn=(FARPROC)LoadLibraryPtr;
ci.pvArg0=ModuleNamePtr;
PerformCallBack4(&ci); in this place process exit. visual studio output message : "process exit with code 0xc0000030"
Sleep(500);
CloseHandle(Process);
return GetDllHandle(ProcessId,ModuleName)!=NULL;
}
extern "C"
{
BOOL SetKMode(BOOL fMode);
DWORD SetProcPermissions(DWORD newperms);
};
#define DLLNAME L"MyDll.dll"
int WINAPI WinMain(HINSTANCE hInstance,HINSTANCE hPrevInstance,LPWSTR lpCmdLine,int nShowCmd)
{
WCHAR Path[MAX_PATH];
GetModuleFileName(NULL,Path,MAX_PATH);
wcscpy(wcsrchr(Path,L'\\')+1,DLLNAME);
WCHAR NewPath[MAX_PATH]=L"\\Windows\\";
wcscat(NewPath,DLLNAME);
CopyFile(Path,NewPath,FALSE);
BOOL Res=InjectDll(L"home.exe",L"MyDll.dll");
return 0;
}
the error code is
#define STATUS_INVALID_PARAMETER_MIX 0xC0000030
(maybe too fast for getting the thread infos?)
try to make the "Sleep(500);" before "PerformCallBack4(&ci);"
I have tried, a problem not in it. Any ideas?
I have not found the reason.... I Use other method without performcallback4
Problem with injection dll to cprog.exe process?
I want to inject dll to cprog.exe process. but it doesn't work.
source code.
Code:
VOID
InjectDllToCprog()
{
WCHAR DllPath[MAX_PATH] = L"";
CallbackInfo ci;
GetModuleFileName(NULL, DllPath, MAX_PATH);
PWCHAR p = wcsrchr(DllPath, L'\\');
DllPath[p - DllPath] = '\0';
wcscat(DllPath, L"\\CprogInject.dll");
ZeroMemory(&ci, sizeof(ci));
g_hCprog = FindCprogProcess(L"Cprog.exe"); // the handle is right.
if(g_hCprog != NULL)
{
DWORD dwMode = SetKMode(TRUE);
DWORD dwPerm = SetProcPermissions(0xFFFFFFFF);
FARPROC pFunc = GetProcAddress(GetModuleHandle(L"Coredll.dll"), L"LoadLibraryW");
ci.ProcId = (HANDLE)g_hCprog;
ci.pFunc = (FARPROC)MapPtrToProcess(pFunc, g_hCprog);
ci.pvArg0 = MapPtrToProcess(DllPath, GetCurrentProcess());
g_InjectCprog = (HINSTANCE)PerformCallBack4(&ci, 0, 0, 0);
if(GetLastError() != 0) // GetLastError() = 5
DbgError(L"PerformCallBack 执行失败", GetLastError());
SetKMode(dwMode);
SetProcPermissions(dwPerm);
}
}
GetLastError() return 0x00000005(Access is denied)
Anyone can help me? Sorry for my poor english.
Ive looked but havnt managed to find a windows .exe convertor to windows mobile. Ive found a program which can shutdown remote pcs on the same network and want to port it to my windows mobile (6.1) - HTC Kaiser.
Ive installed the visual studio and the sdk aswell as the 2.0 mobile framework.
Any ideas where to go from here?
Thanks
Source code to Windows App...
Code:
//-----------------------------------------------------------
// Remote Shutdown v1.0 Console Mode
// Copyright (C) 2002, MATCODE Software
// http://www.matcode.com
// Author: Vitaly Evseenko
//-----------------------------------------------------------
#include <windows.h>
#include <stdlib.h>
#include <stdio.h>
#pragma hdrstop
int RemoteShutdown(LPSTR lpMachineName, LPSTR lpMessage,
DWORD dwTimeout, BOOL bForceAppsClosed,
BOOL bRebootAfterShutdown )
{
HANDLE hToken;
TOKEN_PRIVILEGES TokenPrivileges;
OpenProcessToken( GetCurrentProcess(),
TOKEN_ADJUST_PRIVILEGES | TOKEN_QUERY, &hToken ) ;
LookupPrivilegeValue( NULL, SE_REMOTE_SHUTDOWN_NAME, &(TokenPrivileges.Privileges[0].Luid));
TokenPrivileges.PrivilegeCount = 1;
TokenPrivileges.Privileges[0].Attributes = 2;
AdjustTokenPrivileges( hToken, FALSE, &TokenPrivileges,
sizeof(TOKEN_PRIVILEGES), NULL, NULL );
if(!InitiateSystemShutdown(
lpMachineName, // name of computer to shut down
lpMessage, // address of message to display
dwTimeout, // time to display dialog box
bForceAppsClosed, // force applications with unsaved changes flag
bRebootAfterShutdown ))
{
return GetLastError();
}
return 0;
}
void OutUsage(void)
{
printf("\nUsage: RSD-CON ComputerName [Message] [/tnn] [/f] [/s]\n");
printf("\tComputerName - remote computer name\n");
printf("\tMessage - specify message to display\n");
printf("\t/t - time to display message (nn seconds)\n");
printf("\t/f - do not force applications with unsaved changes flag\n");
printf("\t/s - the computer is to shut down.\n");
printf("Example: RSD-CON PC_LARRY This computer will be restarted now. /t20\n");
}
void main( int argc, char *argv[] )
{
char szMachineName[100];
char szMessage[200];
DWORD dwTimeout;
BOOL bForceAppsClosed;
BOOL bRebootAfterShutdown;
int i, Err;
printf("Remote Shutdown v1.0, Console\n");
printf("Copyright (C) 2002, MATCODE Software\n");
printf("http://www.matcode.com\n");
if (GetVersion() & 0x80000000) // Not Windows NT/2000/XP
{
printf("\n\tThis is a Windows NT/2000/XP application.\n"
"This program will not work on Windows 95/98/ME !\n");
return;
}
if(argc<2)
{
OutUsage();
return;
}
strcpy(szMachineName, argv[1]);
dwTimeout = 0;
bForceAppsClosed = TRUE;
bRebootAfterShutdown = TRUE;
szMessage[0] = '\0';
for( i = 2; i < argc; i++ )
{
// if not started with / then message ;-)
if( argv[i][0] != '/')
{
strcat(szMessage, argv[i]);
strcat(szMessage, " ");
continue;
}
// parse option type
if(argv[i][1]=='t' || argv[i][1]=='T')
{
dwTimeout = atol(&argv[i][2]);
}
else if(argv[i][1]=='f' || argv[i][1]=='F')
{
bForceAppsClosed = FALSE;
}
else if(argv[i][1]=='s' || argv[i][1]=='S')
{
bRebootAfterShutdown = FALSE;
}
}
if (dwTimeout == 0 && szMessage[0])
{
dwTimeout = 5;
}
Err = RemoteShutdown(szMachineName, szMessage,
dwTimeout, bForceAppsClosed,
bRebootAfterShutdown );
if(Err)
{
LPSTR lpstErr = "\0";
if(Err == 53)
{
lpstErr = "The network path was not found.\n"
"Invalid computer name or is not Windows NT/2000/XP machine.\n";
}
else if(Err == 5)
{
lpstErr = "Access is denied. You have no administrative rights on the specified computer.\n";
}
printf("\nUnable to shutdown computer %s, Error: %d.\n%s",
szMachineName, Err, lpstErr);
OutUsage();
}
else
{
printf("\nComputer %s is shut down.\n", szMachineName);
}
}
Hi
This is not that easy. While a lot API calls exists in both Windows and WinMo I doubt that the ones used in this tool are available.
cool this is one development many people is waiting for, especially me
wish you good luck
Hi..interesting topics anyway.
As long as the APIs used in Windows app are also available in Windows Mobile, that will be possible IMO.
The one I'm sure about, the Windows Mobile apps built using .net, will also be available to run in Windows
Hello everyone,
This topic is not new however i never see any thread that has the solution for WM6. In my case, i want to create an smartphone app send AT Command to the gsm modem of my HTC HD.
Apparently there's no port COM2 or COM9 open in the device (everytime i tried CreateFile there's error 55, i also checked in the active device registry, no COM2 or COM9), so i use RIL_Initialize and RIL_GetSerialPortHandle to get the port. The openning and writing steps works very well, however there's no data in return, seems that the modem doesn't respond.
Below is the code:
Code:
RIL_Initialize(1,
ResultCallback,
NotifyCallback,
dwNotifications,
dwParam,
&RilHandle);
HANDLE hCom = NULL;
char * xpos;
char rsltstr[5];
DWORD returnValue;
DWORD LAC;
DWORD CellId;
int bufpos;
DCB dcb;
COMMTIMEOUTS to;
DWORD nWritten;
DWORD event1;
DWORD nRead;
char outbuf[20], buf[256];
BYTE comdevcmd[2]= {0x84, 0x00};
GetSerialPortHandleResult = RIL_GetSerialPortHandle(RilHandle,&hCom);
if (FAILED(GetSerialPortHandleResult))
{
TCHAR szString[256];
wsprintf(szString, L"Error GetSerialPortHandle, result= %d",GetSerialPortHandleResult);
MessageBox(NULL, szString, L"Error", MB_OK | MB_ICONERROR);
return 0;
}
if (hCom==NULL || hCom==INVALID_HANDLE_VALUE)
{
TCHAR szBuf[80];
DWORD dw = GetLastError();
// get the most uptodate cells
_stprintf(szBuf, TEXT("CreateFile failed with error %d."), dw);
MessageBox(0, szBuf, TEXT("Error"), MB_OK);
hCom= NULL;
return -1;
}
if (!GetCommState(hCom, &dcb))
{
return -2;
}
dcb.BaudRate= CBR_115200;
dcb.ByteSize= 8;
dcb.fParity= false;
dcb.StopBits= ONESTOPBIT;
if (!SetCommState(hCom, &dcb))
{
return -3;
}
if (!EscapeCommFunction(hCom, SETDTR))
{
return -4;
}
if (!GetCommTimeouts(hCom, &to))
{
return -6;
}
to.ReadIntervalTimeout= 0;
to.ReadTotalTimeoutConstant= 200;
to.ReadTotalTimeoutMultiplier= 0;
to.WriteTotalTimeoutConstant= 20000;
to.WriteTotalTimeoutMultiplier= 0;
if (!SetCommTimeouts(hCom, &to))
{
return -7;
}
if (!SetCommMask(hCom, EV_RXCHAR))
{
return -8;
}
if (!DeviceIoControl (hCom,0xAAAA5679L, comdevcmd,sizeof(comdevcmd),0,0,0,0))
{
TCHAR szBuf[80];
DWORD dw = GetLastError();
// get the most uptodate cells
_stprintf(szBuf, TEXT("DeviceIoControl failed with error %d."), dw);
MessageBox(NULL,szBuf, TEXT("Error"), MB_OK);
return -9;
}
bufpos = 0;
strcpy(outbuf,"AT+creg=2\r");
if (!WriteFile(hCom, outbuf, strlen(outbuf), &nWritten, NULL))
{
return -10;
}
if (nWritten != strlen(outbuf))
{
return -11;
}
/*if (!WaitCommEvent(hCom, &event1, NULL)) // ALWAYS BLOCKED !!!
{
return -12;
}*/Sleep(500);
while(1)
{
if (!ReadFile(hCom, buf+bufpos, 256 - bufpos, &nRead, NULL))
{
return -13;
}
if (nRead == 0) // ALWAYS BREAKS !!!
break;
bufpos += nRead;
if (bufpos >= 256)
break;
}
strcpy(outbuf,"AT+creg?\r");
... // Continue to write and read
As i said above, there's no return error, just that the buffer read is empty...
Any ideas ?
Thanks!
I don't know why it always gets nRead = 0, all the other steps work very well, no error return ...
I saw several discussions about this, so i do believe that someone have tried once this dev in WM5 or 6...
Therefore could anyone please share some point ?
no one has an idea ?
There's something a little bit interesting that i found out directly in the memory.
There's a sequence of responses to AT Command writing in ASCII:
@HTCCSQ:3
@HTCCSQ:4
@HTCCSQ:2
+CREG: 1,"000C","9F60" (here we has current LAC + Cell ID)
+CREG: 1,"000C","9BC7" (another LAC + Cell ID, i think it's the previous one)
+COPS: 0,2,"20820",3 (inside the "" are MCC MNC)
@HTCCSQ:3 .... (there's plenty of @HTCCSQ: coming next )
Look like some kind of log of the querries of RIL driver to the modem (i'm not sure)
So i think the gsm modem is available for answering to the commands, just haven't figured out how to make a stream connection to it (in WM6).
Any ideas ?
Thanks.
TAPI
I heard somewhere that we can use TAPI to send some AT Command, my question is to know if we can send a custom command (for example AT+CCED) by using TAPI ?
hi,I met the same problem.Do you find the answer?
Thanks.